Can the tractor's cabin allow the noise at the operator's station?PODE ATENUAR O RUÍDO NO POSTO DO OPERADOR?

Autores

  • Aldir Carpes Marques Filho Agricultural Engineering Department - Federal University of Lavras - UFLA, Lavras, MG, Brazil.
  • kléber Pereira Lanças Department of Rural Engineering, Faculty of Agronomic Sciences, São Paulo State University - UNESP, Botucatu, SP, Brazil.

DOI:

https://doi.org/10.18011/bioeng.2022.v16.1071

Palavras-chave:

ergonomics, agricultural tractor operator, workplace safety

Resumo

Constant exposure to high noise levels can cause health problems for agricultural machinery operators. Machines equipped with closed cabs can attenuate noise and preserve the operator from an unhealthy condition. Some studies show that in cabin tractors it is possible to renounce the use of hearing protection, however indoor equipment and air conditioning can reach high levels of noise, which need to be further investigated. The present study aimed to evaluate the noise emitted by a cabined agricultural tractor, in different points, inside and outside cabin, in the engine rotations of 800rpm, 2180rpm and 2500rpm. In each reading, 100 noise intensity values were automatically collected, over two minutes with the aid of a digital decibel meter device. The results were compared with the levels assumed by Annex 1 of the regulatory Brazilian standard NR 15, and it was found that the cabin was able to isolate the noise emitted by the engine and its external components in 15%, however, the internal noise reached 81dB(A). The cabin can attenuate external noise and offer a healthy working environment, however, in long working hours it is recommended to use personal protective equipment such as ear protectors.

Downloads

Não há dados estatísticos.

Referências

Alves, A. D. D. S., Costa, F. R. L. D., Cortez, J. W., Dantas, A. C. D. S., Nagahama, H. D. J. (2011). Níveis de potência sonora emitidos por trator agrícola em condições estáticas e dinâmicas. Pesquisa Agropecuária Tropical, 41, 110-119. DOI: https://doi.org/10.5216/pat.v41i1.9741

Andrade, M., Santos, P., Sartori, J. (2017). Avaliação de parâmetros ergonômicos: ruído e temperatura no posto operacional de tratores agrícolas. Convergências: Revista de Investigação e Ensino das Artes., 10(19), 1-6.

Associação Brasileira De Normas Técnicas – ABNT. NBR 9999; medição do nível de ruído, no posto de operação de tratores e máquinas agrícolas. Rio de Janeiro: 1987.

Baesso, M. M., Modolo, A. J., Baesso, R. C. E., Fischer, C. (2017). Níveis de ruído emitidos por tratores agrícolas. Revista Brasileira de Engenharia de Biossistemas, 11(3), 229-238. DOI: https://doi.org/10.18011/bioeng2017v11n3p229-238

BRASIL. Ministério do Trabalho e Emprego. Portaria 3.214, de jul. 1978. Normas regulamentadoras de segurança e saúde no trabalho - NR 15: Atividades e Operações Insalubres. Brasília, 1978. Disponível em: < https://enit.trabalho.gov.br/>. Acesso em: 10 dez. 2020.

Cunha, J. P. A. R.; Teodoro, R. E. F. (2006). Avaliação do nível de potência sonora em derriçadores e pulverizadores motorizados portáteis utilizados em lavouras de café. Bioscience Journal, Uberlândia, v. 22, n. 3, p. 71-77.

Damasceno, F. A., Soares, C. M., Oliveira, C. E. A., Araújo, G., Ferraz, S., Saraz, J. A. O. (2019). Avaliação do Nível de Ruído Emitido por um Trator Agrícola Acoplado a uma Colhedora de Milho. Revista Engenharia na Agricultura, 27(5), 412-419. DOI: https://doi.org/10.13083/reveng.v27i5.889

Fundacentro. (2001). Fundação Jorge Duprat Figueiredo de Segurança e Medicina do Trabalho. Norma de higiene ocupacional: procedimento técnico: avaliação da exposição ocupacional ao ruído. São Paulo, 40 p.

Gonçalves, L. M., Ferraz, G. A., Oliveira, M. S. D., Barbosa, B. D., Silva, C. J. D., Ferraz, P. F. (2019). Characterization of noise emitted by a power tiller through geostatistics. Revista Brasileira de Engenharia Agrícola e Ambiental, 23, 223-228. DOI: https://doi.org/10.1590/1807-1929/agriambi.v23n3p223-228

Menezes, J. S. R., Paulino, N. J. A. Efeitos do Ruído no Organismo: Manual de Avaliação e Controle do Ruído. 3ª Ed. LTr. p. 62-72. São Paulo. 2004.

Noronha, E. H., Travaglia Filho, U. J., Garavelli, S. L. Quantificação dos níveis de ruídos num estande de tiros da PM do Distrito Federal. Humanitates. 2005; 1.

Oliveira, G. S. A., de Oliveira Júnior, G. G., Rezende, R. N., de Ramos, L. E., Ramos, J. A., Ramirio, L. D., ... & do Valle Coutinho, P. R. (2020). Variabilidade Espacial do Nível de Ruído em um Conjunto Trator-Pulverizador sob Diferentes Rotações no Cafeeiro. Brazilian Journal of Development, 6(11), 86094-86101. DOI: https://doi.org/10.34117/bjdv6n11-143

Poje, A., Potočnik, I. G. O. R., Danilović, M. I. L. O. R. A. D., Antonić, S. L. A. V. I. C. A. (2016). A case study of the impact of skidding distance on tractor operator exposure to noise. Baltic Forestry, 22(2), 357-364.

Silva, J. A. R. D., Oliveira Júnior, G. G. D., Costa, C. E. D. M., Silva, A. B. D., Gabriel, C. P. C., Putti, F. F. (2018). Occupational noise level in mechanized and semimecanized harvest of coffee fruits. DOI: https://doi.org/10.25186/cs.v13i4.1468

Silveira, J. D., Fernandes, H. C., Rinaldi, P. C. N., Modolo, A. J. (2007). Níveis de ruído em função do raio de afastamento emitido por diferentes equipamentos em uma oficina agrícola. Engenharia na agricultura, 15(1), 66-74.

Veiga, R. K., Gontijo, L. A., Masiero, F. C., Venturi, J. (2021). Análise e distribuição espacial do ruído no posto de trabalho do operador e nas proximidades de máquinas agrícolas e florestais. Ciência Florestal, 31, 43-65. DOI: https://doi.org/10.5902/1980509816116

Downloads

Publicado

30-09-2022

Como Citar

Marques Filho, A. C., & Lanças, kléber P. (2022). Can the tractor’s cabin allow the noise at the operator’s station?PODE ATENUAR O RUÍDO NO POSTO DO OPERADOR?. Revista Brasileira De Engenharia De Biossistemas, 16. https://doi.org/10.18011/bioeng.2022.v16.1071

Edição

Seção

Regular Section