HEAD LOSSES ACROSS MICROIRRIGATION LATERALS

Authors

  • GABRIEL GRECO DE GUIMARÃES CARDOSO Escola Superior de Agricultura "Luiz de Queiroz", Universidade de São Paulo (USP), Av. Pádua Dias 11, 13418-900, Piracicaba, São Paulo, Brasil.
  • JOSÉ ANTÔNIO FRIZZONE Escola Superior de Agricultura "Luiz de Queiroz", Universidade de São Paulo (USP), Av. Pádua Dias 11, 13418-900, Piracicaba, São Paulo, Brasil.

DOI:

https://doi.org/10.18011/bioeng2007v1n2p147-162

Keywords:

friction factor, turbulent flow, smooth pipes, obstruction index, obstruction

Abstract

Microirrigation lateral design procedure needs to evaluate accurately both the pipe headlosses and the local losses that are due to the protrusion of emitter barbs into the flow.These local losses, in fact (in relation to the high number of emitters located along theline) can become significant compared to the overall energy loss. On this paper, the resultsof an experimental study on the pipe head losses, friction factor and head local losses forsmall-diameter polyetilene pipes are reported. The experiment was carried out using arange of Reynolds number between 6000 to 72000, obtained by varying discharge at 202 oC water temperature. Five internal diameter pipes were used: 10,0, 13,0, 16,3, 17,4and 19,7 mm; and four connector models with a protrusion areas of 19,70, 23,59, 26,50 e31,63 mm2. According to the results analysis and experimental conditions the frictionfactor (f) of the Darcy-Weisbach equation can be estimated with c = 0,300 and m = 0,25.The Blasius equation (c = 0,316 and m = 0,25) gives a overestimative of f (5,1%). Toderive an estimating procedure of K, the geometry of the connection between the emitterand the pipe was characterized by the obstruction index IO, which is dependent on theratio (r) between the pipe cross-section area corresponding to the section in which theemitter is located, and the pipe cross-section area. A power relationship was then fitted tothe experimental IO, K data pairs. The selection form of the relationship is consistent withthe physical phenomenon since it estimates K = 0 for r = 1 (no obstruction into the pipe).For 6000<R<72000 the relationship was K = 1,23 (IO)0,51 with R2 = 0,9556 and standardfitted error equal to 0,04245. The differences between K observed values and the calculatedones are normally distributed.

Downloads

Download data is not yet available.

References

AL-AMOUND, A. I. Significance of energylosses due to emitter connections in trickleirrigation lines. Jounal of AgricultureEngineering Research., Silsoe, UK, v.60, n.1,p.1-5, 1995.

ALVES, P.R.V. Análise de um coeficientegeométrico para estimativa de perdas de cargaem linhas laterais de irrigação por gotejamento.São Carlos, 2000. 163p. Dissertação(Mestrado) – Escola de Engenharia de SãoCarlos, Universidade de São Paulo.

ALVES, P.R.V.; PORTO, R. Coeficientegeométrico para estimativa da perda de cargalocalizada em linhas laterais de irrigação porgotejamento. Engenharia Agrícola,Jaboticabal, SP, v.22, n.1, p.51-59, 2002.

BAGARELLO,V.; FERRO, V.; PROVENZANO,G.; PUMO, D. Experimental study on flow-resistance law for small-diameter plastic tipes.Journal of Irrigation and Drainage Engineering,New York, v.121, n.5, p.313-316, 1995.

BAGARELLO, V., FERRO,V., PROVENZANO,G., PUMO, D. Evaluating pressure losses indrip-irrigation lines. Journal of Irrigation andDrainage Engineering, New York, v.123, n.1,p.1-7, 1997.

CAMARGO, A.P.; SENTELHAS, P.C. Avaliaçãodo desempenho de diferentes métodos deestimativa da evapotranspiração potencial noestado de São Paulo, Brasil. Revista Brasileirade Agrometeorologia, Santa Maria, RS, v.5, n.1,p.89-97, 1997.

HATHOOT, H.M.; AL-AMOUND, A.I.;MOHAMMAD, F.S. Analysis and design oftrickle-irrigation laterals. Journal of Irrigationand Drainage Engineering, New York, v.119,n.5, p.756-767, 1993.

HOWELL, T.A.; BARINAS, F.A. Pressureloss across trickle irrigation fitting andemitters. Transactions of the ASAE, St.Joseph, MI, v.23, n.4, p.67-72, 1980.

JUANA, L., RODRIGUES-SINOBAS, L;LOSADA, A. Determining minor headlosses in drip irrigation laterals. I:Methodology. Journal of Irrigation andDrainage Engineering, New York, v.128,n.6, p.376-384, 2002a.

JUANA, L., RODRIGUES-SINOBAS, L;LOSADA, A. Determining minor headlosses in drip irrigation laterals. II:Experimental study and validation."Journal of Irrigation and DrainageEngineering, New York, v.128, n.6, p.385-396, 2002b.

KAMAND, F.Z. Hydraulic friction factor forpipe flow. Journal of Irrigation andDrainage KANG, Y.; NISHIYAMA, S.;CHEN, H. Design of microirrigation lateralon nonuniform slops, Irrigation Science,Sidney, MT, , v.17, n.1, p.3-14, 1996.

MONTGOMERY, D.C.; RUNGER, G.C.Estatística aplicada e probabilidade paraengenharia. 2. ed. Rio de Janeiro: LivrosTécnicos e Científicos, 463p. 1999.

MORRIS, H.M; WIGGERT, J.M. Appliedhydraulics in engineering. 2. ed. NewYork: John Wiley, 1972. 629p.

PALAU-SALVADOR, G.; SANCHIS, L.H.;GONZÁLEZ-ALTOZANO, P.; ARVIZA-VALVERDE, J.Real local lossesestimation for on-line emitters usingempirical and numerical procedures.Journal of Irrigation and DrainageEngineering, New York, v.132, n.6, p.522-530, 2006.

PORTO, R.M. Hidráulica básica. SãoCarlos: EESC/USP, 1998. 540p.

PROVENZANO, G.; PUMO, D.Experimental analysis of local pressurelosses for microirrigation laterals. Journalof Irrigation and Drainage Engineering,New York, v.130, n.4, p.318-324, 2004.

PROVENZANO, G.; PUMO, D.; DI DIO,P. Simplified procedure to evaluate headlosses in drip irrigation lateral. Journal ofIrrigation and Drainage Engineering, NewYork, v.131, n.6, p.525-532, 2005.

ROMEO, E., ROYO, C., MONZÓN, A.Improved explicit equations for estimationof the friction factor in rough and smoothpipes. Chemical Engineering Journal,Amsterdam, v.8, n.3, p.369-374, 2002.

SERGHIDES, T. K. Estimate frictionfactor accurate. Chemical EngineeringJournal, Amsterdam, v.91, n.5, p.63-64,1984.

SONNAD, J.R.; GOUDAR, C.T.Turbulent flow friction factor calculationusing a mathematically exact alternativeto the Colebrook-White equation. Journalof Hydraulics Engineering, New York,v.132, n.8, p.863-867, 2006.

SWAMEE, P.K.; JAIN, A.K. Explicitequations for pipe-flow problems. Journalof Hydraulics Division, New York, v.102,n.5, p.657-664, 1976.

VILELA, L.A.A.; SOCCOL, O.J.;GERVÁZIO, E.S.;FRIZZONE, J.A.;BOTREL, T.A. Alteração no diâmetro detubos de polietileno submetidos adiferentes pressões. Revista Brasileirade Engenharia Agrícola e Ambiental,Campina Grande, v.7, n.1, p.182-185,2003.

VON BERNUTH, R.D.; WILSON, T. Frictionfactors for small diameter plastic pipes. Journalof Irrigation and Drainage Engineering, NewYork, v.115, n.2, p.183-192, 1989.

VON BERNUTH, R. D. Simple and accuratefriction loss equation for plastic pipe. Journalof Irrigation and Drainage Engineering, NewYork, v.116, n.2, p.294-298, 1990.

YOO, D.H.; SINGH, V.P. Two methods for thecomputation of commercial pipe friction factors.Journal of Hydraulics Engineering, New York,v.131, n.8, p.694-704, 2005.

WU, I.P. Energy gradient line for direct hydrauliccalculation in drip irrigation design. IrrigationScience, Amsterdam, v.13, n.1, p.21-29, 1992.

WU, I. P., GITLIN, H. M. Energy gradient linefor drip irrigation laterals. Journal of Irrigationand Drainage Division, New York, v.101, n.4,p.323-326, 1975.

WU, I.P. An assessment of hydraulics designof micro-irrigation systems. Agricultural WaterManagement, Amsterdam, v.32, n.3, p.275-284, 1997.

WILLMOTT, C.J. On the validation of models.Physical Geography, Canada, v.2, n.2, p.184-195, 1981.

ZAYANI, K.; ALOUINI, A.; LEBDI, F.;LAMADDALENA, N. Design of drip irrigationsystems using the energy drop ratio approach.Transactions of the ASAE, St. Joseph, MI, v.44,n.5, p.1127-1133, 2001.

Published

2007-11-10

How to Cite

CARDOSO, G. G. D. G., & FRIZZONE, J. A. (2007). HEAD LOSSES ACROSS MICROIRRIGATION LATERALS. Revista Brasileira De Engenharia De Biossistemas, 1(2), 147–162. https://doi.org/10.18011/bioeng2007v1n2p147-162

Issue

Section

Regular Section